| Report no. | BP-SAMPLE | Date of issue | 20 November 2026 |
|---|---|---|---|
| Lot | Sample only | Revision | 0, issued for information |
| Local government | City of Melville | Rules version | 2026-11-19 |
| Zoning and site | R20, 860 m², 20 m frontage | Existing house | As described by the owner |
| Basis | Desktop assessment against the published State and council rules, using the title boundary and the information supplied. No site inspection or survey. | ||
General information and estimates to help you prepare, not advice for your circumstances. Confirm with your council and a licensed surveyor, and speak to a licensed financial adviser or accountant, before you commit money. Details on the last page.
Today · front + rear lot
| Option | Today | Draft 2027 |
|---|---|---|
| Granny flat up to 70 m² now, 90 m² proposed | Likely no planning approval needed | 90 m² limit and no extra car bay, if adopted |
| Subdivide R20: min 350 m², average 450 m² | Possible with a 5% variation | Yes, 2 lots if adopted |
Likely no planning approval needed
A granny flat (“ancillary dwelling”) of up to 70 m² internal floor area doesn’t need planning approval when it meets every deemed-to-comply rule below. A building permit is always needed.
| ✓ | Size 70 m² is within the 70 m² internal floor area limit. |
| ✓ | Open space Your block allows 430 m² of roofed area. With about 205 m² already roofed, roughly 225 m² is left, enough for a 70 m² flat (about 81 m² to the outside of the walls). |
| ? | Outdoor living area The main house must keep an outdoor living area of at least 30 m² after the flat is built. |
| ? | Location on the block The flat must sit behind the street setback line (6 m from the front boundary at R20), so usually in the back yard. |
| ? | Side and rear setbacks For a single-storey flat, walls without major windows generally need 1 m from side and rear boundaries (1.5 m for walls longer than 14 m), and 1.5 m where walls have major openings. A 70 m² flat is often about 7 × 10 m, so plan for a clear area of roughly 9 × 11.5 m. |
| ? | Parking Unless your block is in a "Location A" area close to frequent public transport, one extra on-site car bay is required (the draft codes propose removing this). |
| ✓ | City of Melville lot size The council’s granny flat guidance still lists a 450 m² minimum lot, an older State rule removed in April 2024. Yours is 860 m², so it doesn’t matter either way. |
| One-bedroom granny flat, built | A$110,000–160,000 |
| Two-bedroom granny flat, built | A$140,000–210,000 |
| Site works and service connections | A$15,000–40,000 |
| Weekly rent, inner Perth (5–10 km from CBD) | A$450–600 |
| Weekly rent, middle ring (10–20 km) | A$380–500 |
| Weekly rent, outer suburbs | A$300–420 |
Worked example: a A$175k two-bedroom build plus A$25k site works, rented at A$450 a week, earns about A$23,400 a year, a gross return of about 11.7% before rates, insurance, vacancy, maintenance and tax. Your figures will differ; get quotes.
Nothing in what you told us, or what we looked up, stops your best option outright. The items below apply to most blocks and are quick to rule out.
| Ref | Risk | What it means, and what to do | Rating |
|---|---|---|---|
| R1 | Sewer lines and easements | A sewer main or an easement across the back of the block limits where you can build. Check your title and ask for the sewer diagram before designing. | Check |
| R2 | Power pole, trees and crossover | A power pole on the far side of the street, a street tree where a crossover must go, or large trees on site all add cost or need approval. | Check |
| R3 | Asbestos | Houses and sheds built before about 1990 often contain asbestos. Any demolition needs a licensed removalist. | Check |